Импульсный блок питания Phoenix Contact QUINT-PS/1AC/24DC/3,5, 2866747
5 580 р.
| Technical data | |
| Dimensions | |
| Width | 32 mm |
| Height | 130 mm |
| Depth | 125 mm |
| Width with alternative assembly | 122 mm |
| Height with alternative assembly | 130 mm |
| Depth with alternative assembly | 35 mm |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | ? 95 % (at 25 °C, non-condensing) |
| Noise immunity | EN 61000-6-2:2005 |
| Maximum altitude | 5000 m |
| Input data | |
| Nominal input voltage range | 100 V AC ... 240 V AC |
| Input voltage range | 85 V AC ... 264 V AC |
| 90 V DC ... 350 V DC | |
| Dielectric strength maximum | 300 V AC |
| AC frequency range | 45 Hz ... 65 Hz |
| Frequency range DС | 0 Hz |
| Discharge current to PE | < 3.5 mA |
| Inrush surge current | < 20 A (typical) |
| Power failure bypass | > 20 ms (120 V AC) |
| > 80 ms (230 V AC) | |
| Input fuse | 5 A (slow-blow, internal) |
| Choice of suitable circuit breakers | 6 A ... 20 A (AC: Characteristics B, C, D, K) |
| Type of protection | Transient surge protection |
| Protective circuit/component | Varistor |
| Output data | |
| Nominal output voltage | 24 V DC ±1 % |
| Setting range of the output voltage (USet) | 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted) |
| Nennausgangsstrom (IN) | 3.5 A (-25°C ... 60°C, UOUT = 24 V DC) |
| POWER BOOST (IBoost) | 4 A (-25°C ... 40°C permanent, UOUT = 24 V DC ) |
| Selective Fuse Breaking (ISFB) | 15 A (12 ms) |
| Derating | 60 °C ... 70 °C (2.5%/K) |
| Connection in parallel | Yes, for redundancy and increased capacity |
| Connection in series | Yes |
| Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
| < 2 % (change in load, dynamic 10 % ... 90 %) | |
| < 0.1 % (change in input voltage ±10 %) | |
| Residual ripple | < 50 mVPP (with nominal values) |
| Output power | 84 W |
| Typical response time | < 0.05 s |
| Maximum power dissipation in no-load condition | 3.5 W |
| Power loss nominal load max | 11 W |
| General | |
| Net weight | 0.5 kg |
| Operating voltage display | Green LED |
| Efficiency | > 88 % (for 230 V AC and nominal values) |
| Insulation voltage input/output | 4 kV AC (type test) |
| 2 kV AC (routine test) | |
| Protection class | I |
| MTTF/ MTBF (IEC 61709, SN 29500) | > 1433000 h (25 °C) |
| > 820000 h (40°C) | |
| > 360000 h (60°C) | |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| Assembly instructions | Alignable: 5 mm horizontally, 15 mm next to active components, 50 mm vertically |
| Connection data, input | |
| Connection method | Pluggable screw connection |
| Conductor cross section solid min. | 0.2 mm? |
| Conductor cross section solid max. | 2.5 mm? |
| Conductor cross section flexible min. | 0.2 mm? |
| Conductor cross section flexible max. | 2.5 mm? |
| Conductor cross section AWG min. | 20 |
| Conductor cross section AWG max | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Connection data for signaling | |
| Conductor cross section solid min. | 0.2 mm? |
| Conductor cross section solid max. | 2.5 mm? |
| Conductor cross section flexible min. | 0.2 mm? |
| Conductor cross section flexible max. | 2.5 mm? |
| Conductor cross section AWG min | 20 |
| Conductor cross section AWG max. | 12 |
| Screw thread | M3 |