Siemens Simatic 6ES7214-1HG31-0XB0
29 294 р.
| General information | |
| Engineering with | |
| Programming package | STEP 7 V11 SP2 or higher |
| Supply voltage | |
| 24 V DC | Yes |
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| Load voltage L+ | |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 5 V |
| permissible range, upper limit (DC) | 250 V |
| Input current | |
| Current consumption (rated value) | 500 mA ; Typical |
| Current consumption, max. | 1.2 A ; 24 V DC |
| Inrush current, max. | 12 A ; at 28.8 V |
| Encoder supply | |
| 24 V encoder supply | |
| 24 V | Permissible range: 20.4V to 28.8V |
| Output current | |
| Output current Current output to backplane bus (5 V DC), max. | 1600 mA ; Max. 5 V DC for SM and CM |
| Power loss | |
| Power loss, typ. | 12 W |
| Memory | |
| Type of memory | EEPROM |
| usable memory for user data | 75 kbyte |
| Work memory | |
| integrated | 75 kbyte |
| expandable | No |
| Load memory | |
| integrated | 4 Mbyte |
| Backup | |
| present | Yes ; maintenance-free |
| without battery | Yes |
| CPU processing times | |
| for bit operations, typ. | 0.085 µs ; / instruction |
| for word operations, typ. | 1.7 µs ; / instruction |
| for floating point arithmetic, typ | 2.5 µs ; / instruction |
| CPU-blocks | |
| Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used |
| OB | |
| Number, max | Limited only by RAM for code |
| Data areas and their retentivity | |
| retentive data area in total (incl. times, counters, flags), max. | 10 kbyte |
| Flag | |
| Number, max. | 8 kbyte ; Size of bit memory address area |
| Address area | |
| I/O address area | |
| I/O address area, overall | 1024 bytes for inputs / 1024 bytes for outputs |
| Process image | |
| Inputs, adjustable | 1 kbyte |
| Outputs, adjustable | 1 kbyte |
| Hardware configuration | |
| Number of modules per system, max. | 3 comm. modules, 1 signal board, 8 signal modules |
| Time of day | |
| Clock | |
| Hardware clock (real-time clock) | Yes |
| Deviation per day, max. | 60 s/month at 25 °C |
| Backup time | 480 h ; Typical |
| Digital inputs | |
| Number of digital inputs | 14 ; Integrated |
| of which inputs usable for technological functions | 6 ; HSC (High Speed Counting) |
| integrated channels (DI) | 14 |
| m/p-reading | Yes |
| Number of simultaneously controllable inputs | |
| all mounting positions | |
| up to 40 °C, max | 14 |
| Input voltage | |
| Rated value, DC | 24 V |
| for signal "0" | 5 V DC at 1 mA |
| for signal "1" | 15 VDC at 2.5 mA |
| Input current | |
| for signal "1", typ. | 1 mA |
| Input delay (for rated value of input voltage) | |
| for standard inputs | |
| parameterizable | 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
| at "0" to "1", min. | 0.2 ms |
| at "0" to "1", max | 12.8 ms |
| for interrupt inputs | |
| parameterizable | Yes |
| for counter/technological functions | |
| parameterizable | Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz |
| Cable length | |
| Cable length, shielded, max. | 500 m ; 50 m for technological functions |
| Cable length unshielded, max. | 300 m ; For technological functions: No |
| Digital outputs | |
| Number of digital outputs | 10 ; Relays |
| integrated channels (DO) | 10 |
| Short-circuit protection | No ; to be provided externally |
| Switching capacity of the outputs | |
| with resistive load, max. | 2 A |
| on lamp load, max. | 30 W with DC, 200 W with AC |
| Output delay with resistive load | |
| "0" to "1", max. | 10 ms ; max. |
| "1" to "0", max. | 10 ms ; max. |
| Switching frequency | |
| of the pulse outputs, with resistive load, max. | 1 Hz |
| Relay outputs | |
| Max. number of relay outputs, integrated | 10 |
| Number of relay outputs | 10 |
| Number of operating cycles, max | mechanically 10 million, at rated load voltage 100,000 |
| Cable length | |
| Cable length, shielded, max. | 500 m |
| Cable length unshielded, max. | 150 m |
| Analog inputs | |
| integrated channels (AI) | 2 ; 0 to 10 V |
| Number of analog inputs | 2 |
| Input ranges | |
| Voltage | Yes |
| Input ranges (rated values), voltages | |
| 0 to +10 V | Yes |
| Input resistance (0 to 10 V) | ?100k ohms |
| Cable length | |
| Cable length, shielded, max. | 100 m ; twisted and shielded |
| Analog outputs | |
| Number of analog outputs | 0 |
| Analog value generation | |
| Integration and conversion time/resolution per channel | |
| Resolution with overrange (bit including sign), max. | 10 bit |
| Integration time, parameterizable | Yes |
| Conversion time (per channel) | 625 µs |
| Encoder | |
| Connectable encoders | |
| 2-wire sensor | Yes |
| 1. Interface | |
| Interface type | PROFINET |
| Physics | Ethernet |
| isolated | Yes |
| automatic detection of transmission rate | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Functionality | |
| PROFINET IO Controller | Yes |
| Communication functions | |
| S7 communication | |
| supported | Yes |
| as server | Yes |
| as client | Yes |
| Open IE communication | |
| TCP/IP | Yes |
| ISO-on-TCP (RFC1006) | Yes |
| UDP | Yes |
| Web server | |
| supported | Yes |
| User-defined websites | Yes |
| Test commissioning functions | |
| Status/control | |
| Status/control variable | Yes |
| Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Forcing | |
| Forcing | Yes |
| Diagnostic buffer | |
| present | Yes |
| Integrated Functions | |
| Number of counters | 6 |
| Counting frequency (counter) max. | 100 kHz |
| Frequency meter | Yes |
| controlled positioning | Yes |
| PID controller | Yes |
| Number of alarm inputs | 4 |
| Galvanic isolation | |
| Galvanic isolation digital inputs | |
| Galvanic isolation digital inputs | 500V AC for 1 minute |
| between the channels, in groups of | 1 |
| Galvanic isolation digital outputs | |
| Galvanic isolation digital outputs | Relays |
| between the channels | No |
| Permissible potential difference | |
| EMC | |
| Interference immunity against discharge of static electricity | |
| Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | Yes |
| Test voltage at air discharge | 8 kV |
| Test voltage at contact discharge | 6 kV |
| Interference immunity to cable-borne interference | |
| on the supply lines acc. to IEC 61000-4-4 | Yes |
| Interference immunity on signal cables acc. to IEC 61000-4-4 | Yes |
| Interference immunity against voltage surge | |
| on the supply lines acc. to IEC 61000-4-5 | Yes |
| Interference immunity against conducted variable disturbance induced by high-frequency fields | |
| Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | Yes |
| Emission of radio interference acc. to EN 55 011 | |
| Emission of radio interference acc. to EN 55 011 (limit class A) | Yes ; Group 1 |
| Emission of radio interference acc. to EN 55 011 (limit class B) | Yes ; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
| Degree and class of protection | |
| IP20 | Yes |
| Standards, approvals, certificates | |
| CE mark | Yes |
| CSA approval | Yes |
| UL approval | Yes |
| cULus | Yes |
| RCM (former C-TICK) | Yes |
| FM approval | Yes |
| Marine approval | |
| Marine approval | Yes |
| Ambient conditions | |
| Operating temperature | |
| min. | -20 °C |
| max. | 60 °C |
| horizontal installation, min. | -20 °C |
| horizontal installation, max. | 60 °C |
| vertical installation, min. | -20 °C |
| vertical installation, max. | 50 °C |
| min. | -40 °C |
| max. | 70 °C |
| Air pressure | |
| Operation, min. | 795 hPa |
| Operation, max | 1080 hPa |
| Storage/transport, min. | 660 hPa |
| Storage/transport, max | 1080 hPa |
| Relative humidity | |
| Operation, max | 95 % ; no condensation |
| Vibrations | |
| Vibrations | 2G wall mounting, 1G DIN rail |
| Operation, tested according to IEC 60068-2-6 | Yes |
| Shock test | |
| tested according to IEC 60068-2-27 | Yes ; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
| Dimensions | |
| Width | 110 mm |
| Height | 100 mm |
| Depth | 75 mm |
| Weights | |
| Weight, approx. | 435 g |